| |
| |
Click on image to enlarge
|
| Product Name |
Listing Number |
Price |
| Welch Allyn AED 10, Automated External Defibrillator |
283930 |
$2,332.40 |
|
| Description |
| Features of the Welch Allyn AED 10: • Text and voice instructions guide the user through the rescue. • Color-coded pads and illustrations ensure proper pad placement. • Escalating energy (200 J, 300 J, 360 J); energy protocol can be changed to meet specific needs. • High-performance battery delivers up to five years of standby performance or over 90 discharges at 360 joules. • Internal memory stores event data including ECG waveforms, time/date stamps, shock delivery and system actions. • Lightweight and compact—ideal for small spaces. • Compatible with major manufacturer defibrillator pads. • AEDs are now being placed in a wide range of business and public settings... and the Welch Allyn AED 10 is leading the way by helping rescuers respond quickly to an emergency. • One high-performance, long-life, maintenance-free lithium battery is all that is required to power the AED 10. General Specifications: • Weight: 3.5 lbs with battery (1.6 kg). • Size: 8.25"" x 6.875"" x 2.75"" (210 x 175 x 70 mm). • Operating Temperature: 32 to 122 °F (0 to 50 °C). • Storage Temperature: -22 to 158 °F (-30 to 70 °C) without battery. • Humidity: Up to 95% noncondensing. • Altitude: Up to 15,000 feet (-150 to 4570 m). • Shock: Mil Std 810E method 516.4, procedure 1 (40 G, 6-9 ms pulse, 1/2 sine each axis). • Vibration: Mil Std 810 method 514.4, category 1. • Ingress Protection: IEC 60529 IP24. • Drop Test: Mil Std 810F method 516.5, procedure IV (1-meter drop onto any edge, corner, or surface). Defibrillator: • Output: Welch Allyn Biphasic Truncated Exponential. • Energy Select: 150, 200, 300 J or 200, 300, 360 J (user configurable). • Charge Time: Less than 5 seconds to 150 J, less than 15 seconds to 360 J. • Analysis Time: 4 to 16 seconds. • Audible Prompts: 18 audible prompts. • Visual Prompts: 20 text screen prompts. • Controls: Four buttons: On/Off, Shock, and 2 software-configurable buttons. • Accuracy: ±10% or 1 J (whichever is greater) at 50Ω. Display: • Size: 2.1"" x 1.4"" (54 x 36 mm). • Type: Backlit monochrome LCD. • Display Resolution: 160 x 100 pixels. Battery: • Nonrechargeable: LiMnO2 12 V, 2.6 Ah. • Capacity: 90 discharges at 360 J or 125 discharges at 200 J or 150 discharges at 150 J or 5 hours' ECG monitoring. • Shelf Life: 77 °F ± 59 °F (25 °C ± 15 °C) 10 years' (5 years' storage + 5 years' standby); 5 years' standby (after installation)*. *Capacity may be diminished at operating temperature extremes. Electrical Isolation: • Power: Unit operates on internal battery only. • External Electrical Connections: No external devices are attached to the unit. • Risk Current Category: Internally powered equipment with defibrillator-proof BF type patient applied parts (as per definition of IEC 60601-1 standard). Electromagnetic Compatibility: • Radiated Emissions: EN55011; CISPR11 B. • ESD: EN61000-4-2; 8 kV air, 6 kV contact. • Radiated Susceptibility: EN61000-4-3 (10 V/m (20 V/m EN60601-2-4)). • Magnetic Field Emissions: AAMI DF2 4.3.18.1). Data Management: • Event Documentation: Internal. • Internal Memory Capacity: 1 MB (250 4-sec ECG samples or 3,000 time-stamped events). • Quick Report: Treatment Summary, Event Log, Test Log. • Communication: RS-232 via infrared (IR) port to PC with SmartLinkTM Event Pro or SmartLinkTM Lite Software. |
|
| Condition |
Quantity Available |
Date Available |
|
Unlimited |
|
|
| Manufacturer |
Model Number |
Model Year |
| Welch Allyn |
WA-970300E |
|
|
| Serial Number |
Inventory Number |
SKU Number |
|
|
|
|
| Shipping |
Product Location |
Location Zip Code |
|
|
|
|
|
|
|
|
|
|
|
|