| Product Name |
Listing Number |
Price |
| Refurbished - Puritan Bennett 7200 and 7200 AE Critical Care Ventilator |
58294 |
Call for Price |
|
| Description |
| The Puritan Bennett 7200 respiratory ventilator has an advanced micro-processor design that offers CMV assistcontrol SIMV CPAP PEEP and sigh controls. This critical care ventilator has a built-in nebulizer airoxygen blender and variable pressure waveforms. Data is clear on the digital display and easy to input with the keyboard control. The Puritan Bennett 7200 and 7200AE are available refurbished from DRE. Product Features State-of-the-art gas delivery system. Demonstrated track record of reliability Full-featured microprocessor-controlled ventilator with 7202 display screen. Gas delivery features - Flow-by Pressure Support Pressure Control Ventilation Patient monitoring features - Graphics 2.0 Respiratory Mechanics Auto-PEEP Communications features - RS-232 Digital Communications Interface DCI 2.0 Optional 7250 Metabolic Monitor Integrated safety systems Optional humidifier is available with this unit. Indications For Usage For use in providing pediatric and adult patients with ventilatory support in the hospital environment. Specifications: Ventilator Dimensions: 41.9 cm H x 57.2 cm D x 55.9 cm W 16.5 in x 22.5 in x 22 in Ventilator Weight: 50.8 kg 112 lbs Operator Selected Parameters Tidal Volume: .1 to 2.5 liters Respiratory Rate: .5 to 70 bpm Max Peak Inspiratory Flow: 120 Ipm during mandatory breather 180 Ipm during spontaneous breathing. Sensitivity Inspiratory: .5 to 20 cmH2O bellow PEEP Oxygen Percentage: 21 to 100 Plateau: 0 to 2 seconds PEEP CPAP: .1 to 2.5 liters not to exceed twice tidal volume Sigh Rate and Frequency: 1 to 15 sighs per hour 1 to 3 sighs per event. Operator Selected Alarm Thresholds High Airway Pressure: 10 to 120 cmH2O Low Airway Pressure: 3 to 99 cmH2O PEEP CPAP Pressure: 0 to 45 cmH2O Exhaled Tidal Volume: 0 to 2.5 liters Low Exhaled Minute Volume: 0 to 60 liters High Respiratory Rate: 0 to 70 bpm Sigh High Airway Pressure: 10 to 120 cmH2O not to exceed twice high airway pressure. Ventilatory Modes: Operator selectable. Continuous Manditory Ventilation CMV. Synchronous Intermitte |
|
| Condition |
Quantity Available |
Date Available |
| Reconditioned |
Unlimited |
|
|
| Manufacturer |
Model Number |
Model Year |
| Puritan Bennett |
|
|
|
| Serial Number |
Inventory Number |
SKU Number |
|
|
|
|
| Shipping Details |
Product Location |
Location Zip Code |
|
|
40223 |
|
| Return Policy |
| Call for more information. |
|
| Acceptable Payment Types |
| American Express, Visa, Master Card, Purchase Order or Check. |
|
|
|