The medical equipment/medical product listed below is owned and sold by: This web site is powered by MEDmarketplace.com  
  Ardus Medical
Cincinnati, OH 45242
    
 
Ardus Medical is a supplier for hospitals and other healthcare organizations around the world with brand name used medical equipment at a savings of 30-80% versus the cost of new medical equipment.
 
     
 
 
Click on image
to enlarge




Product Name Listing Number Price
Plum 5000 12265 $600.00
Description
CALL FOR PRICING PRODUCT SPECIFICATIONS Dimensions: Approximately 18 x 23 x 23 cm (7 x 9 x 9 in), excluding pole clamp protrusion and power cord storage. Weight: Approximately 6.0 Kg (13 lb), with battery. Casing: High-impact plastic Power requirements: 110-120 VAC, 50/60 Hz, 30 W. Power Cord: Hospital-grade AC cord. 8 ft long, with transparent Plug and retainer plate. Fuses: 0.5 A, 250 V, Slow Blowing. Battery: One sealed, lead-acid, rechargeable 8 V battery, Internal to device. Accessible for ease of field replacement, with color-coded leads and polarized connector. Battery life (new batteries, full charge, at 20 C) approximately 500 mL total volume delivered or six hours of operation, whichever occurs first. Delivery Rate Range Micro Mode: 0.1 to 99.9 mL/hr (in o.1 mL. Increments) The total of the primary rate plus the secondary rate Cannot exceed 99.9 mL/hr in Micro Mode. Note: While using the concurrent delivery feature in the Micro Mode, neither the primary rate nor the secondary rate can be less than 0.5 mL/hr. Macro Mode: 1 to 999 mL/hr (in 1 mL increments. the total of the primary rate plus the secondary rate cannot exceed 700 mL/)in 1 mL/hr in Macro Mode Dose Limit Range Micro Mode: 0.1 to 999 mL (in 0.1 mL increments). Macro Mode: 1 to 9999 mL (in 1 mL increments). Operating Backpressure -2 to 10 psig. The maximum pressure is user-selectable from 1 to 10 psig, via the front panel touch switches. Secondary Doses: For dual-channel delivery, a single dose of a secondary fluid may be administered. For multidose delivery, 1 to 24 doses of a secondary fluid may be administered at intervals from 15 minutes to 24 hours. Occlusion Alarm Distal: The Distal Occlusion alarm sounds within two pumping cycles after the distal set tubing or set outlet fitting becomes occluded. Proximal: The Proximal Occlusion alarm sounds within five pumping cycles if the tubing proximal to the cassette becomes occluded. Air-in-alarm: The Stopped Air In Distal Line alarm will sound if a bubble 100 uL or larger passes the distal air-in-line sensors. (alarm may actually sound at detection of a bubble as small as 50 uL.) Proximal: The Stopped Air In Proximal Line alarm will sound if approximately 1200 uL or more passes through the proximal air-in-line sensors.
Condition Quantity Available Date Available
15
Manufacturer Model Number Model Year
Abbott 5000
Serial Number Inventory Number SKU Number
Shipping Details Product Location Location Zip Code
Return Policy
Acceptable Payment Types
Visa, Mastercard
Terms and Conditions

Home | Terms of Service | Privacy Policy | Our Sellers | Payment Solutions | Shipping Solutions
Media Center | Advertise with Us | MEDbroker | About Us | Contact Us

© 2002-2008 MEDmarketplace.com, Inc. All rights reserved.
The best way to buy and sell medical equipment, medical supplies, medical products, and hospital equipment.