The medical equipment/medical product listed below is owned and sold by: This web site is powered by MEDmarketplace.com  
  Ardus Medical
Cincinnati, OH 45242
    
 
Ardus Medical is a supplier for hospitals and other healthcare organizations around the world with brand name used medical equipment at a savings of 30-80% versus the cost of new medical equipment.
 
     
 
 
Click on image
to enlarge




Product Name Listing Number Price
Colleague Triple 12263 $3,195.00
Description
CALL FOR CURRENT PRICING PRODUCT SPECIFICATIONS Ac power Requirements: 100-120 VAC, 60Hz Leakage Current: Less than 300 u amps earth leakage (tested per UL 2601) External Fuses: 1.6 amp Type T (time delay) 250V Power Cord: 2.9 m (9 feet) long with integrally molded hospital grade plug Battery Supply System: Colleague 3 Pump - 3 hours operating time at 100 mL/hr for all three channels (fully charged new batteries) 12 hours to recharge to 80% of capacity Internal charge system recharges batteries whenever the device is connected to an AC outlet Range of Programmable Flow Rates: Primary Infusion on each pump channel 0.1 to 99.9 mL/hr in 0.1 mL/hr increments 1 to 1200 mL/hr in 1 mL/hr increments Piggyback Infusion on each pump channel 0.1. to 99.9 mL/hr in 0.1 mL/hr increments 1 to 500 mL/hr in 1 mL/hr increments Note: Rate limits can be configured for values less Than those stated above. Volume to be Infused: 0.1 - 99.9 mL in 0.1 mL increments 1- 9999 mL mL/hr in 1 mL increments Note: Volume to be Infused limits can be configured for values less than those stated above KVO: 0.1 - 5 mL/hr in 0.1 mL increments (configurable option) or programmed rate whichever is less. Priming rate: 500 mL/hr (to be used only when not connected to patient) Advance Air Rate to Advanced an Air Bubbles: At the same rate programmed for the current primary or piggyback infusion. Air Bubble Setting: Measured accumulations of approximately 25 microliters 50 microliters 100 microliters 150 microliters The Air Bubble Setting is a configurable option. Auto Restart: Allows the pump channel to automatically restart if an occlusion is relieved within one minute after detection. This configuration option allows 0 to 9 restarts before manual intervention is required. Nominal Downstream: Alarm sensitivity is a configurable option. Rate range in mL/hr <21 21- 200 >200 2 psig 4 psig 6 psig Minimum 5 psig 8 psig 11 psig Moderate 9 psig 12 psig 15 psig Maximum Device Size: Approximately 13.88" H x 7.75" W x 8.00" D (353 x 197 x 203 mm) Not including clamp knob or power cord Device weight: Approximately 17.5 lbs (7.9 kg) Environmental Operating Limits: 59º F - 100º F (15º C - 38º C) Environmental Storage and Transport Limits: -20º F - 135º F (-29ºC - 57º C), 10-100% Reliable Humidity including condensation, 500-1060 hPa Barometric Pressure Ground Impedance: Less than 0.2 ohms (tested per UL-2601) Solution Container Height: Pump will operate at all programmable flow rates with a solution container height ranging from -36 to +48 inches. Container height is measured from the pump channel selected for use. Interfaces: Attachment to a remote nurse call system A variety of systems exist which enable alert and alarm conditions to be transmitted to a remote location via the communications port on the rear panel assembly of the pump. See the service manual for additional information.
Condition Quantity Available Date Available
10
Manufacturer Model Number Model Year
Baxter CT
Serial Number Inventory Number SKU Number
Shipping Details Product Location Location Zip Code
Buyer pays shipping (cost to be determined later) 45242
Return Policy
Acceptable Payment Types
Visa, Mastercard
Terms and Conditions

Home | Terms of Service | Privacy Policy | Our Sellers | Payment Solutions | Shipping Solutions
Media Center | Advertise with Us | MEDbroker | About Us | Contact Us

© 2002-2008 MEDmarketplace.com, Inc. All rights reserved.
The best way to buy and sell medical equipment, medical supplies, medical products, and hospital equipment.