| PRODUCT SPECIFICATIONS
Ac power Requirements: 100-120 VAC, 60Hz
Leakage Current: Less than 300 u amps earth leakage (tested per UL 2601)
External Fuses: 1.6 amp Type T (time delay) 250V
Power Cord: 2.9 m (9 feet) long with integrally molded hospital grade plug
Battery Supply System: 5 hours operating time at 100 mL/hr (fully charged new batteries) 8 hours to recharge to 80% of capacity. Internal charge system recharges batteries whenever the device is connected to an AC outlet
Range of Programmable Flow Rates: Primary Infusion: 0.1 to 99.9 mL/hr in 0.1 mL/hr increments
1 to 1200 mL/hr in 1 mL/hr increments
Piggyback Infusion: 0.1. to 99.9 mL/hr in 0.1 mL/hr increments
1 to 500 mL/hr in 1 mL/hr increments
Note: Rate limits can be configured for values less Than those stated above.
Volume to be Infused: 0.1 - 99.9 mL in 0.1 mL increments 1- 9999 mL mL/hr in 1 mL increments
Note: Volume to be Infused limits can be configured for values less than those stated above
KVO: 0.1 - 5 mL/hr in 0.1 mL increments (configurable option) or programmed rate whichever is less.
Priming rate: 500 mL/hr (to be used only when not connected to patient)
Advance Air Rate to Advanced an Air Bubbles: At the same rate programmed for the current primary or piggyback infusion.
Air Bubble Setting: Measured accumulations of approximately
25 microliters
50 microliters
100 microliters 150 microliters
The Air Bubble Setting is a configurable option.
Auto Restart: Allows the pump channel to automatically restart if an occlusion is relieved within one minute after detection. This configuration option allows 0 to 9 restarts before manual intervention is required.
Nominal Downstream: Alarm sensitivity is a configurable option. Rate range in mL/hr
<21 21- 200 >200
2 psig 4 psig 6 psig Minimum
5 psig 8 psig 11 psig Moderate
9 psig 12 psig 15 psig Maximum
Device Size: Approximately 10" H x 7.75" W x 7.75" D
(254 x 197 x 197 mm)
Not including clamp knob or power cord
Device weight: Approximately 10.4 lbs (4.7kg)
Environmental Operating Limits: 59º F - 100º F (15º C - 38º C)
Environmental Storage and Transport Limits: -20º F - 135º F (-29ºC - 57º C), 10-100% Reliable Humidity including condensation, 500-1060 hPa Barometric Pressure
Ground Impedance: Less than 0.2 ohms (tested per UL-2601)
Solution Container Height: Pump will operate at all programmable flow rates with a solution container height ranging from -36 to +48 inches. Container height is measured from the pump channel selected for use.
Interfaces: Attachment to a remote nurse call system A variety of systems exist which enable alert and alarm conditions to be transmitted to a remote location via the communications port on the rear panel assembly of the pump. See the service manual for additional information.
|
|
| Condition |
Quantity Available |
Date Available |
|
20 |
|
|
| Manufacturer |
Model Number |
Model Year |
| Baxter |
CS |
|
|
| Serial Number |
Inventory Number |
SKU Number |
|
|
|
|
| Shipping Details |
Product Location |
Location Zip Code |
| Buyer pays shipping (cost to be determined later) |
|
45242 |
|
|
|
| Acceptable Payment Types |
| Visa, Mastercard |
|
|
|